![]() Reset feature automacally resumes all sengs back to factory default sengs. System menu allows seng the 9 parameters, including the date and me, resoluon, etc. Help message as a operaonal guide that helps user quickly begin using the meter. ![]() Password protecon prevents the unauthorized calibraon and sengs. Hold funcon freezes current reading for easy viewing and recording. Connuous measurement mode that can used for indexing and matching the sample vials. SS conversion factor ensures accurate measurement for Total Suspended Solids. Selectable four turbidity units, including the NTU, FNU, EBC and ASBC. 2 to 7 points calibraon using the Formazin Standards. LMTB200 Salient Features MODEL LMTB200 SPECIFICATIONS SCIENTIFIC INSTRUMENTS R HSN Code : 90275090 Catalogue 2021-22 Measurement Range 0~2000 NTU, 0~500 EBC, 0~9999 ASBC, Resoluon 0.01 (0~100 NTU), 0.1 (100~999 NTU), 1 (999~2000 NTU) Accuracy ☒% of reading for 0~500 NTU, ☓% of reading for 501~2000 NTU Calibraon Points 2 to7 points ( 0.02, 10.00, 200, 500, 1000, 1500, 2000 NTU ) TSS Range deponding on the TSS conversion factor TSS Accuracy +3% of reading Light Source Infrared-eming diode (850 nm wavelength) Detector Silicon Photodiode Stray Light < 0.02 NTU Sample Vials 60 (H) × 25 (Dia)mm Memory Stores up to 200 data sets Display 4.5” TFT display Operang Temperature 0~50☌ Power Requirements DC12V/2A, using AC adapters, 220VAC/50Hz Dimensions LxWxH (mm) & Weight 250 × 177 × 96 mm & 1.2kg STANDARD ACCESSORIES : Empty Vial - 1no, Calibraon Standards - 3,(200NTU, 500NTU, 1000NTU) Cloth, 12V Power Adaptor, Test Cerficate, Instrucon Manual urbidity meter is equipped with a 4.5" TFT display. Turbidity Meter Specifications are subject to change without notice. Perfect Calibiration Sytem All baseline, wavelength, dark current can be calibrated automatically to keep good running conditions.Software Functions ( Optional ) Multi functions operated directly on the spectrophotometer and display the test results' curve and data: wavelength scanning, standard curve, kinetics, multi wavelength scanning, DNA/protein test. 6 INCHES LCD DISPLAY LMSPUV1900 series have a 6 inches LCD display to show results and curves directly on the screen. Optical Base LMSPUV1900 series use a rigid 16mm diecast aluminum base as their optical mount to ensure the stability and reliability.Long Path Light Design LMSPUV1900 unique 520mm long light path design greatly improved resolution and the bandwidth can reach 0.5nm.Path Design: Double Beam LMSPUV1900 double light design can prevent circuit fluctuation and stray light to ensure stability of the instrument.Real time clock for date & time stamping of results. Lamp Selection enables conserving the life of D2 & Tungsten lamps. The two detectors are used to measure sample and reference respectively and simultaneously for optimizing measurement accuracy.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |